TCOMMAND OPERATING INSTRUCTIONS V1.3 09-03-2009 V18 SOFTWARE.DOC Page 5
3. INSTALLATION
OPERATING VOLTAGE
The T-Command requires 9VDC @ 500mA the LCD back light requires the full 9VDC to start. If the unit is
supplied with less the keyboard will light and then fail. The T-Command can also be supplied with power by
the CAT 5 cable fig 1.
Fig. 1 Note the connections below are at the T-Command & the Tx would be Rx at the MATRIX / CPU end of
the cable.
1 =+9Vdc SUPPLY
2 =+9Vdc SUPPLY
3 = TxA (TO MATRIX / CPU)
4 = RxA (FROM MATRIX / CPU)RxB (FROM MATRIX / CPU) = 5
TxB (TO MATRIX / CPU) = 6
0V SUPPLY = 7
0V SUPPLY = 8
BLUE
WHITE/GREEN
ORANGE
WHITE/BLUE
GREEN
WHITE/BROWN
BROWN WHITE/ORANGE
White/Blue, Blue, White/Orange, Orange, White/Green, Green, White Brown, Brown,
are the recommended CAT5 & 6 Colours